China Excessive Frequency Inverter Hybrid Solar Inverter with Constructed-in MPPT PWM Solar Charge Controller on World Sources, Excessive Frequency Inverter, Solar Inverter, Inverter – World Sources

HP / HP-T solar inverter (1KW ~ 7.2KW) Model: HP / HP-T 10212 32224 50248 72248 rated capacity 1000W 3200W 5000W 7200W Peak power (20 ms) 3000VA 9600VA 15KVA 21.6 KVA Battery voltage 12VDC 24VDC 48VDC 48VDC Product size (L * W * Hmm) 411.5x283x88 476x350x118 538x388x118 Package size (L * W * Hmm) 459X345X147 502x402x165 561X454X167 NW (Kg) 7th 11.5 11.8 16 GW (Kg) 8th 12.5 12.8 17.5 Inside
MPPT
Solar
Regulator
(Optional) Charging mode MPPT Rated PV input voltage 360VDC MPPT tracking voltage range 120V-450V Max. PV input voltage Voc
(At lowest temperature) 500V Maximum output of the PV generator 1500W 4000W 4000W * 2 MPPT tracking channels (input channels) 1 1 2 Inside
PWM
Solar
Regulator
(Optional) Charging mode PWM Charging current 30A 60A / 120A PV input voltage range 15V-44V 30V-44V 60V-88V Max. PV input voltage Voc
(At lowest temperature) 50V 100V Maximum output of the PV generator 420W 1680W / 3360W 3360W / 6720W PV input channels 1 1 or 2 entrance DC input voltage range 10.5VDC-15VDC 21VDC-30VDC 42VDC-60VDC Nominal AC input voltage 220VAC / 230VAC / 240VAC AC input voltage range 170VAC ~ 280VAC (UPS mode) / 120VAC ~ 280VAC (INV mode) AC input frequency range 45Hz ~ 55Hz (50Hz) , 55Hz ~ 65Hz (60Hz) output Output efficiency (battery / PV mode) 94% (peak value) Output voltage (battery / PV mode) 220 V AC ± 2% / 230 V AC ± 2% / 240 V AC ± 2% Output frequency (battery / PV mode) 50 Hz ± 0.5 or 60 Hz ± 0.5 Output shaft (battery / PV mode) Pure sine wave Efficiency (AC mode) > 99% Output voltage (AC mode) Follow input Output frequency (AC mode) Follow input Distortion of the output waveform ≤3% (linear load) No loss of load (battery mode) ≤1% nominal power No loss of load (AC mode) ≤1% nominal power (Charger does not work in AC mode) battery battery
Type VRLA battery Charging voltage: 13.8 V; Float voltage: 13.7 V (single battery voltage) Adjust battery Charging and discharging parameters of different battery types can be customized according to user requirements (charging and discharging parameters of different battery types can be set via the control panel) Maximum charging current (grid or PV or grid + PV) (model with integrated MPPT controller) 40A 60A 50A 60A Maximum charging current
(Model with built-in PWM controller) Netz40A +
Charge current of the PWM controller Netz60A +
Charge current of the PWM controller Netz50A +
Charge current of the PWM controller Netz60A +
Charge current of the PWM controller Loading method Three-stage (constant current, constant voltage, trickle charge) protection Low battery alarm Battery undervoltage protection value + 0.5 V (single battery voltage) Battery undervoltage protection Factory setting: 10.5 V (single battery voltage) Battery overvoltage alarm Constant charging voltage + 0.8 V (single battery voltage) Battery overvoltage protection Factory setting: 17V (single battery voltage) Battery overvoltage recovery voltage Battery overvoltage protection value -1V (single battery voltage) Overload protection Automatic protection (battery mode), breaker or insurance (AC mode) Output short circuit protection Automatic protection (battery mode), breaker or insurance (AC mode) Temperature protection > 90 ° C (switch off output) Working mode Grid priority / solar priority / battery priority (can be set) Transfer time 4ms advertisement LCD + LED Thermal method Cooling fan in intelligent control Communication (optional) RS485 / APP (WIFI monitoring or GPRS monitoring)